Lebotek LBT Drop Hammer Rig — Siemens PLC Reprogramming & Automatic Free-Fall Fault Fix

Siemens S7-1200 PLC cabinet on Lebotek LBT 1.5-HPMEZ drop hammer rig

A large UK piling contractor contacted us with a Lebotek LBT 1.5-HPMEZ fully electric drop hammer rig that had developed a fault with its automatic free-fall system. The rig was out of action and the contractor needed it back on site as quickly as possible. As manufacturers of our own automatic free-fall systems for drop hammer rigs, and with extensive experience across a wide range of PLC platforms, we were well placed to diagnose and resolve the fault.

The rig is controlled by a Siemens S7-1200 PLC, connected via PROFINET. We attended site with our Panasonic Toughbook running Siemens TIA Portal, connected directly to the PLC via Ethernet — allowing us to go online with the controller, read the live programme, diagnose the fault, and carry out the reprogramming on site without the rig needing to leave.

The visit also turned up something the operator wasn't aware of — but more on that below.

The Lebotek LBT 1.5-HPMEZ

Lebotek LBT control panel showing fault display Lebotek LBT control panel brake time and drop time adjustment controls

The Lebotek LBT control panel — the display showing the fault condition (left) and the brake time and drop time adjustment controls (right).

The Lebotek LBT 1.5-HPMEZ is a fully electric drop hammer rig designed for automatic free-fall piling. The automatic free-fall system controls the release and retrieval of the hammer — including brake timing and drop height — through a PLC-managed sequence. When this system develops a fault, the rig cannot operate safely in automatic mode, which is the primary working mode for production piling.

Our Background Noakes Engineering designs and manufactures its own automatic free-fall systems for drop hammer rigs. This gives us a fundamental understanding of how these control systems work — the logic sequences, safety interlocks, and timing parameters involved — that goes well beyond general PLC programming experience. When a fault develops on a system like this, we know what we're looking for.

Siemens S7-1200 PLC — Diagnosis & Reprogramming

Full view of Siemens S7-1200 PLC cabinet on Lebotek LBT drop hammer rig

The Siemens S7-1200 PLC cabinet — CPU, signal board, and I/O modules controlling the full free-fall sequence.

Siemens S7-1200 PLC CPU and PROFINET module on Lebotek rig Siemens S7-1200 SB1221 signal board on Lebotek PLC

The S7-1200 CPU with PROFINET module (left) and the SB 1221 DC signal board (right) — the core of the rig's control system.

Siemens S7-1200 PLC PROFINET connection on Lebotek LBT drop hammer rig

PROFINET connection detail — the Ethernet link between the PLC and our Toughbook allowed us to go online with the controller and read the live programme directly.

Siemens TIA Portal running on Panasonic Toughbook connected to Lebotek PLC via Ethernet

Siemens TIA Portal on the Panasonic Toughbook — connected to the S7-1200 via Ethernet, online with the PLC and reading the live programme.

With TIA Portal connected and online, we were able to monitor the programme in real time, identify where the free-fall sequence was failing, and carry out the necessary reprogramming on site. The fault was diagnosed and resolved, with the automatic free-fall system restored to correct operation and verified through test cycles before we left site.

An Unexpected Discovery — Scanreco Remote Control

During the visit, while tracing the wiring and connections within the control cabinet, we identified a Scanreco Central Unit — the receiver unit for a Scanreco radio remote control system. The contractor was entirely unaware the rig had been fitted with a remote control system.

Scanreco Central Unit with Ethernet connections on Lebotek drop hammer rig Scanreco Central Unit wiring inside Lebotek rig control cabinet

The Scanreco Central Unit — receiver for a radio remote control system — found installed in the rig's control cabinet.

Scanreco Central Unit wiring detail on Lebotek LBT drop hammer rig

Wiring detail of the Scanreco Central Unit — fully installed and wired into the rig's control system.

As we also have Scanreco WinSCI installed on the same Toughbook, we were able to connect to the Central Unit and take a full download of its configuration code. This means the contractor now has the complete configuration data needed to purchase a compatible Scanreco PCU remote handset — giving them the option to operate the rig remotely, a capability they didn't know they had.

Why This Matters Remote control operation of a drop hammer rig allows the operator to position themselves with a clear view of the pile and hammer at all times — a significant safety benefit, particularly on confined or congested sites. Having the Central Unit already installed and configured means the contractor needs only to purchase the compatible handset to enable this capability.
Project Summary Lebotek LBT 1.5-HPMEZ fully electric drop hammer rig — automatic free-fall system fault diagnosed and resolved. Siemens S7-1200 PLC reprogrammed on site using Siemens TIA Portal via Ethernet connection on Panasonic Toughbook. Scanreco Central Unit identified and configuration downloaded using Scanreco WinSCI — contractor now holds the code required to purchase a compatible PCU remote handset.
  • Rig: Lebotek LBT 1.5-HPMEZ fully electric drop hammer
  • PLC: Siemens S7-1200 with SB 1221 signal board and PROFINET module
  • Diagnostic software: Siemens TIA Portal — connected via Ethernet on Panasonic Toughbook
  • Remote control system: Scanreco Central Unit — identified, connected, and configuration downloaded using Scanreco WinSCI
  • Outcome: Automatic free-fall system restored; contractor supplied with Scanreco configuration code for future handset purchase

If you have a drop hammer rig, piling machine, or other plant with a PLC fault — whether Siemens, Mitsubishi, Allen-Bradley, or another platform — or if you need a Scanreco system diagnosed, configured, or commissioned, get in touch.

Get in Touch